Use a supervised tabletop model to explore distance changes and false alarms while learning why it cannot detect a seizure or protect a patient.
Prototype objective
The project focuses on sensing, state logic, feedback, and a low-voltage bench prototype that can be tested safely. Define user requirements, success criteria, and failure cases before considering any real deployment.
Suggested components
An Arduino Uno R3, an HC-SR04 ultrasonic sensor, a 16x2 I2C LCD, a yellow LED, an active buzzer, a breadboard, and jumper wires.
Wiring and implementation
The HC-SR04's Trig and Echo pins connect to pins 12 and 13, the buzzer connects to pin 3, the LED to pin 4, and the LCD uses standard I2C wiring.
Use a regulated supply and common ground, never drive loads directly from controller pins, and add current limiting, suitable interface stages, flyback protection for inductive loads, and logic-level conditioning as required.
Test plan
Move a padded mannequin model through standing, sitting, lying, and occluded positions; test clothing, bedding, bystanders, echo timeout, and power loss, then record missed and false detections.
Use limitations
An HC-SR04 measures one distance and cannot diagnose seizures or reliably detect falls. Never use this prototype for patient monitoring, emergency response, or clinical decisions.
Next step
Document the schematic, library versions, calibration, measurements, and failure cases. Whenever the application involves safety, health, children, buildings, or equipment, use qualified specialists and applicable standards rather than relying on a hobby prototype.
Leave your comment